Public water system record
Pendleton Water Association
Serves an area of Sabine Parish, LA · 2,634 people served
Federal records show 64 health-based violations and 30 monitoring/reporting issues for Pendleton Water Association in the last ten years. The most serious issue in this window was a Long Term 2 Enhanced Surface Water Treatment Rule violation that EPA lists as archived, not resolved.
System profile
- Health-based violations, last 10 years
- 64
- Resolved
- 60
- Unresolved
- 0
- Archived by EPA
- 4
- Any acute record
- Yes
- Monitoring issues, last 10 years
- 30
Key facts
- Pendleton Water Association draws water from 1 surface water intake.
- Highest measured level in the last 10 years: Haloacetic Acids (HAA5), 117 µg/L, federal limit 60 µg/L (2 times the limit), 2018.
- Most recent formal enforcement: compliance order (no penalty) by Louisiana, February 2017.
- Record on file since 1996, with 61 health-based violations before October 19, 2016.
- Lead pipe inventory: 0 lead and 0 unknown out of 901 service lines.
Check whether Pendleton Water Association serves your address
Health-based violations
Since October 2016Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.
| Contaminant | Rule family | Start date | Status | Acute |
|---|---|---|---|---|
|
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Dec 1, 2025 |
Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
|
No |
|
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Nov 1, 2025 |
Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
|
No |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Nov 1, 2025 |
Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
|
Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Aug 1, 2025 | Resolved | Yes |
|
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Jun 1, 2025 | Resolved | No |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Jun 1, 2025 | Resolved | Yes |
|
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | May 1, 2025 |
Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
|
No |
|
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Apr 1, 2025 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.083 mg/L, federal limit 0.06 mg/L (1.4 times the limit)
|
220 | Apr 1, 2025 | Resolved | No |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Mar 1, 2025 | Resolved | Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Mar 1, 2025 | Resolved | Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Feb 1, 2025 | Resolved | Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Feb 1, 2025 | Resolved | Yes |
|
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Jan 1, 2025 | Resolved | No |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Jan 1, 2025 | Resolved | Yes |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.082 mg/L, federal limit 0.06 mg/L (1.4 times the limit)
|
220 | Jan 1, 2025 | Resolved | No |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Oct 1, 2024 | Resolved | Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Oct 1, 2024 | Resolved | Yes |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.08 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
|
220 | Oct 1, 2024 | Resolved | No |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Sep 1, 2024 | Resolved | Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Aug 1, 2024 | Resolved | Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Aug 1, 2024 | Resolved | Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Jul 1, 2024 | Resolved | Yes |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Jul 1, 2024 | Resolved | Yes |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
|
220 | Jul 1, 2024 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.077 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
|
220 | Jul 1, 2024 | Resolved | No |
|
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Jun 1, 2024 | Resolved | Yes |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.061 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Apr 1, 2024 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.066 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Jan 1, 2024 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
|
220 | Oct 1, 2023 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.066 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Oct 1, 2023 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.061 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Jul 1, 2023 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
|
220 | Jul 1, 2022 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.062 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Jul 1, 2022 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
|
220 | Apr 1, 2022 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.072 mg/L, federal limit 0.06 mg/L (1.2 times the limit)
|
220 | Apr 1, 2022 | Resolved | No |
|
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
|
120 | Jan 1, 2022 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.069 mg/L, federal limit 0.06 mg/L (1.2 times the limit)
|
220 | Jan 1, 2022 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.066 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Oct 1, 2021 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.062 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Jul 1, 2021 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.062 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Apr 1, 2021 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.063 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Jan 1, 2021 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.067 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Oct 1, 2020 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.071 mg/L, federal limit 0.06 mg/L (1.2 times the limit)
|
220 | Jul 1, 2020 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.079 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
|
220 | Apr 1, 2020 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.077 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
|
220 | Jan 1, 2020 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.06 mg/L (1.4 times the limit)
|
220 | Oct 1, 2019 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.086 mg/L, federal limit 0.06 mg/L (1.4 times the limit)
|
220 | Jul 1, 2019 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.084 mg/L, federal limit 0.06 mg/L (1.4 times the limit)
|
220 | Apr 1, 2019 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.085 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
|
220 | Jan 1, 2019 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.109 mg/L, federal limit 0.06 mg/L (1.8 times the limit)
|
220 | Jan 1, 2019 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 89 µg/L, federal limit 80 µg/L (1.1 times the limit)
|
220 | Oct 1, 2018 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 110 µg/L, federal limit 60 µg/L (1.8 times the limit)
|
220 | Oct 1, 2018 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 102 µg/L, federal limit 80 µg/L (1.3 times the limit)
|
220 | Jul 1, 2018 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 117 µg/L, federal limit 60 µg/L (2 times the limit)
|
220 | Jul 1, 2018 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 117 µg/L, federal limit 80 µg/L (1.5 times the limit)
|
220 | Apr 1, 2018 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 109 µg/L, federal limit 60 µg/L (1.8 times the limit)
|
220 | Apr 1, 2018 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 126 µg/L, federal limit 80 µg/L (1.6 times the limit)
|
220 | Jan 1, 2018 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 94 µg/L, federal limit 60 µg/L (1.6 times the limit)
|
220 | Jan 1, 2018 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 104 µg/L, federal limit 60 µg/L (1.7 times the limit)
|
220 | Oct 1, 2017 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 132 µg/L, federal limit 80 µg/L (1.7 times the limit)
|
220 | Oct 1, 2017 | Resolved | No |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 101 µg/L, federal limit 80 µg/L (1.3 times the limit)
|
220 | Jul 1, 2017 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 87 µg/L, federal limit 60 µg/L (1.5 times the limit)
|
220 | Jul 1, 2017 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 62 µg/L, federal limit 60 µg/L (at or just above the limit)
|
220 | Apr 1, 2017 | Resolved | No |
Monitoring and reporting issues
Since October 2016Missed tests or reports, not contaminants found above a limit.
| Issue | Start date | Status |
|---|---|---|
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Dec 1, 2025 |
Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
|
|
Consumer Confidence Rule
OTHER
|
Jul 1, 2024 | Resolved |
|
Public Notice
OTHER
|
Jun 17, 2024 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
May 1, 2024 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Apr 1, 2024 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Mar 1, 2024 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Feb 1, 2024 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Jan 1, 2024 | Resolved |
|
Surface Water Treatment Rule
Monitoring and reporting
|
Nov 1, 2022 | Resolved |
|
Lead and Copper Rule
Monitoring and reporting
|
Sep 22, 2022 | Resolved |
|
Consumer Confidence Rule
OTHER
|
Jul 1, 2022 | Resolved |
|
Public Notice
OTHER
|
Dec 10, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Nov 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Nov 1, 2021 | Resolved |
|
Lead and Copper Rule
Monitoring and reporting
|
Oct 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Oct 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Sep 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Aug 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Jul 1, 2021 | Resolved |
|
Public Notice
OTHER
|
Jun 19, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Jun 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
May 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Apr 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Mar 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Feb 1, 2021 | Resolved |
|
Surface Water Treatment Rule
Monitoring and reporting
|
Jan 1, 2021 | Resolved |
|
Interim Enhanced Surface Water Treatment Rule
Monitoring and reporting
|
Jan 1, 2021 | Resolved |
|
Public Notice
OTHER
|
Dec 23, 2020 | Resolved |
|
Public Notice
OTHER
|
Jul 9, 2020 | Resolved |
|
Lead and Copper Rule
Monitoring and reporting
|
Oct 1, 2017 | Resolved |
Full record since 1996
EPA's records for Pendleton Water Association go back to 1996. Before October 19, 2016 they list 61 health-based violations (55 resolved, 6 archived by EPA without a recorded fix) and 19 monitoring or reporting violations.
| Violations that began in | Health-based | Monitoring and reporting |
|---|---|---|
| 1990s | 2 | 1 |
| 2000s | 31 | 6 |
| 2010 to October 18, 2016 | 28 | 12 |
| October 19, 2016 to 2019 | 18 | 1 |
| 2020s | 46 | 29 |
Most recent health-based violation before October 19, 2016: Haloacetic Acids (HAA5), began April 2016, Resolved.
Show all 61 health-based violations before October 19, 2016
| Contaminant | Start date | Status |
|---|---|---|
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 106 µg/L, federal limit 60 µg/L (1.8 times the limit)
|
Apr 1, 2016 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 118 µg/L, federal limit 60 µg/L (2 times the limit)
|
Jan 1, 2016 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 90 µg/L, federal limit 80 µg/L (1.1 times the limit)
|
Jan 1, 2016 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 129 µg/L, federal limit 60 µg/L (2.2 times the limit)
|
Oct 1, 2015 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 97 µg/L, federal limit 80 µg/L (1.2 times the limit)
|
Oct 1, 2015 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 91 µg/L, federal limit 80 µg/L (1.1 times the limit)
|
Jul 1, 2015 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 94 µg/L, federal limit 60 µg/L (1.6 times the limit)
|
Jul 1, 2015 | Resolved |
|
Total Coliform
Contaminant limit exceeded
|
Jun 1, 2015 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 83 µg/L, federal limit 80 µg/L (at or just above the limit)
|
Apr 1, 2015 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 64 µg/L, federal limit 60 µg/L (1.1 times the limit)
|
Apr 1, 2015 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 96 µg/L, federal limit 80 µg/L (1.2 times the limit)
|
Apr 1, 2012 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 90 µg/L, federal limit 60 µg/L (1.5 times the limit)
|
Apr 1, 2012 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 73 µg/L, federal limit 60 µg/L (1.2 times the limit)
|
Jan 1, 2012 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 93 µg/L, federal limit 80 µg/L (1.2 times the limit)
|
Jan 1, 2012 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 75 µg/L, federal limit 60 µg/L (1.3 times the limit)
|
Oct 1, 2011 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 95 µg/L, federal limit 80 µg/L (1.2 times the limit)
|
Oct 1, 2011 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 76 µg/L, federal limit 60 µg/L (1.3 times the limit)
|
Jul 1, 2011 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 98 µg/L, federal limit 80 µg/L (1.2 times the limit)
|
Jul 1, 2011 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 101 µg/L, federal limit 60 µg/L (1.7 times the limit)
|
Apr 1, 2011 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 103 µg/L, federal limit 80 µg/L (1.3 times the limit)
|
Apr 1, 2011 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 123 µg/L, federal limit 60 µg/L (2.1 times the limit)
|
Jan 1, 2011 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 115 µg/L, federal limit 80 µg/L (1.4 times the limit)
|
Jan 1, 2011 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 143 µg/L, federal limit 60 µg/L (2.4 times the limit)
|
Oct 1, 2010 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 132 µg/L, federal limit 80 µg/L (1.7 times the limit)
|
Oct 1, 2010 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 175 µg/L, federal limit 60 µg/L (2.9 times the limit)
|
Jul 1, 2010 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 146 µg/L, federal limit 80 µg/L (1.8 times the limit)
|
Jul 1, 2010 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
|
Apr 1, 2010 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
|
Apr 1, 2010 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 92 µg/L, federal limit 60 µg/L (1.5 times the limit)
|
Apr 1, 2009 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 84 µg/L, federal limit 80 µg/L (1.1 times the limit)
|
Apr 1, 2009 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 93 µg/L, federal limit 60 µg/L (1.6 times the limit)
|
Jan 1, 2009 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 94 µg/L, federal limit 60 µg/L (1.6 times the limit)
|
Oct 1, 2008 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 68 µg/L, federal limit 60 µg/L (1.1 times the limit)
|
Jul 1, 2008 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 105 µg/L, federal limit 80 µg/L (1.3 times the limit)
|
Jul 1, 2008 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 74 µg/L, federal limit 60 µg/L (1.2 times the limit)
|
Apr 1, 2008 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 107 µg/L, federal limit 80 µg/L (1.3 times the limit)
|
Apr 1, 2008 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 74 µg/L, federal limit 60 µg/L (1.2 times the limit)
|
Jan 1, 2008 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 112 µg/L, federal limit 80 µg/L (1.4 times the limit)
|
Jan 1, 2008 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 62 µg/L, federal limit 60 µg/L (at or just above the limit)
|
Oct 1, 2007 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 110 µg/L, federal limit 80 µg/L (1.4 times the limit)
|
Oct 1, 2007 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 72 µg/L, federal limit 60 µg/L (1.2 times the limit)
|
Jul 1, 2007 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 62 µg/L, federal limit 60 µg/L (at or just above the limit)
|
Jul 1, 2006 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 69 µg/L, federal limit 60 µg/L (1.2 times the limit)
|
Apr 1, 2006 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 82 µg/L, federal limit 80 µg/L (at or just above the limit)
|
Apr 1, 2006 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 83 µg/L, federal limit 60 µg/L (1.4 times the limit)
|
Jan 1, 2006 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 94 µg/L, federal limit 80 µg/L (1.2 times the limit)
|
Jan 1, 2006 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 91 µg/L, federal limit 60 µg/L (1.5 times the limit)
|
Oct 1, 2005 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 104 µg/L, federal limit 80 µg/L (1.3 times the limit)
|
Oct 1, 2005 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
|
Jul 1, 2005 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
|
Jul 1, 2005 | Resolved |
11 older violations are not listed here. EPA ECHO has the complete list.
Enforcement actions
Louisiana regulators took 5 formal enforcement actions against Pendleton Water Association between 2005 and 2017. The most recent was a compliance order (no penalty) in February 2017.
| Date | By | Action | Violations covered |
|---|---|---|---|
| Feb 16, 2017 | Louisiana | Compliance order (no penalty) | 50 violations (50 health-based): Haloacetic Acids (HAA5), Total Trihalomethanes (TTHMs) |
| Feb 27, 2012 | Louisiana | Compliance order (no penalty) | 39 violations (31 health-based): Total Trihalomethanes (TTHMs), Haloacetic Acids (HAA5), Public Notice, Chloramine |
| Jun 5, 2006 | Louisiana | Compliance order (no penalty) | 40 violations (34 health-based): Total Trihalomethanes (TTHMs), Haloacetic Acids (HAA5) |
| Oct 26, 2005 | Louisiana | Compliance order (no penalty) | 33 violations (27 health-based): Haloacetic Acids (HAA5), Total Trihalomethanes (TTHMs) |
| Jun 9, 2005 | Louisiana | Compliance order (no penalty) | 34 violations (28 health-based): Haloacetic Acids (HAA5), Total Trihalomethanes (TTHMs) |
What the violations mean
Haloacetic Acids (HAA5)
30 incidentsHaloacetic acid byproducts exceeded the federal limit
Long-term exposure to HAAs may increase cancer risk
Interim Enhanced Surface Water Treatment Rule
16 incidentsThe system did not meet a filtration or treatment requirement for surface water
Inadequate treatment of surface water can let pathogens such as Cryptosporidium and Giardia through
Total Trihalomethanes (TTHMs)
11 incidentsDisinfection byproduct levels exceeded the federal limit
Long-term TTHM exposure may increase bladder cancer risk
Long Term 2 Enhanced Surface Water Treatment Rule
7 incidentsThe system failed required surface water treatment or filtration standards
Untreated or inadequately treated surface water can contain bacteria and viruses
Where the water comes from
Pendleton Water Association draws water from 1 surface water intake.
Annual water quality report
Pendleton Water Association must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.
Where the state allows it, systems serving fewer than 10,000 people may publish the report in a local newspaper or news site instead of mailing it, and must provide a copy on request.
Find a posted report with EPA's Consumer Confidence Report search
Testing your own water
To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by Louisiana.
Certified drinking water labs by state EPA guidance for private wells