Public water system record

Royalton Terrace

Serves an area of Windsor County, VT · 60 people served

Federal records show 3 health-based violations and 5 monitoring/reporting issues for Royalton Terrace in the last ten years, including an unresolved LEAD AND COPPER RULE REVISIONS violation.

  • VT0005331
  • VICTORIA
  • MN
  • 60 served

System profile

Source water Groundwater
ZIP 55386
EPA system ID VT0005331

Verify this system on EPA ECHO →

Health-based violations, last 10 years
3
Resolved
2
Unresolved
1
Any acute record
No
Monitoring issues, last 10 years
5

Key facts

  • Royalton Terrace draws water from 1 well.
  • Highest measured level in the last 10 years: Combined Radium (-226 and -228), 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit), 2024.
  • Most recent enforcement action: boil water order by Vermont, November 2002.
  • Record on file since 1991, with 15 health-based violations before October 19, 2016.

Check whether Royalton Terrace serves your address

Address suggestions by Mapbox

Health-based violations

Since October 2016

Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.

Contaminant Rule family Start date Status Acute
LEAD AND COPPER RULE REVISIONS
Treatment technique failure
350 Oct 17, 2024 Active No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Jan 1, 2024 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Oct 1, 2023 Resolved No

Monitoring and reporting issues

Since October 2016

Missed tests or reports, not contaminants found above a limit.

Issue Start date Status
Consumer Confidence Rule
OTHER
Jul 1, 2025 Resolved
Haloacetic Acids (HAA5)
Monitoring and reporting
Jan 1, 2024 Active
Total Trihalomethanes (TTHMs)
Monitoring and reporting
Jan 1, 2024 Active
Consumer Confidence Rule
OTHER
Jul 1, 2022 Resolved
Chlorine
Monitoring and reporting
Oct 1, 2019 Resolved

Full record since 1991

EPA's records for Royalton Terrace go back to 1991. Before October 19, 2016 they list 15 health-based violations (11 resolved, 4 archived by EPA without a recorded fix) and 134 monitoring or reporting violations.

Violations that began in Health-based Monitoring and reporting
1990s 3 2
2000s 12 127
2010 to October 18, 2016 0 5
October 19, 2016 to 2019 0 1
2020s 3 4

Most recent health-based violation before October 19, 2016: Lead and Copper Rule, began August 2006, Resolved.

Show all 15 health-based violations before October 19, 2016
Contaminant Start date Status
Lead and Copper Rule
Treatment technique failure
Aug 22, 2006 Resolved
Lead and Copper Rule
Treatment technique failure
Jun 22, 2006 Resolved
Total Coliform
Contaminant limit exceeded
Sep 1, 2004 Resolved
Total Coliform
Contaminant limit exceeded
Oct 1, 2002 Resolved
Total Coliform
Contaminant limit exceeded
Feb 1, 2002 Archived
Total Coliform
Contaminant limit exceeded
Feb 1, 2002 Resolved
Total Coliform
Contaminant limit exceeded
Jan 1, 2002 Archived
Total Coliform
Contaminant limit exceeded
Jan 1, 2002 Resolved
Total Coliform
Contaminant limit exceeded
Sep 1, 2000 Resolved
Total Coliform
Contaminant limit exceeded
Sep 1, 2000 Archived
Total Coliform
Contaminant limit exceeded
Feb 1, 2000 Resolved
Total Coliform
Contaminant limit exceeded
Feb 1, 2000 Archived
Total Coliform
Contaminant limit exceeded
Jun 1, 1993 Resolved
Total Coliform
Contaminant limit exceeded
Jul 1, 1992 Resolved
Total Coliform
Contaminant limit exceeded
Jun 1, 1992 Resolved

Enforcement actions

Vermont regulators issued 4 boil water orders to Royalton Terrace between 2000 and 2002, filed as 5 records in EPA's data. The most recent was a boil water order in November 2002.

Date By Action Violations covered
Nov 1, 2002 Vermont Boil water order 1 violation (1 health-based): Total Coliform
Mar 1, 2002 Vermont Boil water order 2 violations (2 health-based): Total Coliform
Oct 1, 2000 Vermont Boil water order 1 violation (1 health-based): Total Coliform
Mar 1, 2000 Vermont Boil water order 1 violation (1 health-based): Total Coliform

What the violations mean

Combined Radium (-226 and -228)

2 incidents

Test results for Combined Radium (-226 and -228) were above the federal limit (a maximum contaminant level violation).

The utility had to notify customers about each of these violations.

LEAD AND COPPER RULE REVISIONS

1 incident

The system did not complete a treatment step or action that the LEAD AND COPPER RULE REVISIONS requires (a treatment technique violation).

The utility had to notify customers about this violation.

Where the water comes from

Royalton Terrace draws water from 1 well.

Annual water quality report

Royalton Terrace must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.

Systems serving 500 or fewer people may meet the rule by telling customers the report is available on request, so you may need to ask Royalton Terrace for a copy.

Find a posted report with EPA's Consumer Confidence Report search

Testing your own water

To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by Vermont.