Public water system record

New Baltimore Regional

Serves New Baltimore, Fauquier County, VA · 8,818 people served

Federal records show 1 health-based violation and no monitoring/reporting issues for New Baltimore Regional in the last ten years. The most serious issue in this window was a resolved Combined Radium (-226 and -228) violation.

  • VA6061318
  • WARRENTON
  • VA
  • 8,818 served

System profile

Source water Groundwater
ZIP 20187
EPA system ID VA6061318

Verify this system on EPA ECHO →

Health-based violations, last 10 years
1
Resolved
1
Unresolved
0
Any acute record
No
Monitoring issues, last 10 years
0

Key facts

  • New Baltimore Regional draws water from 13 wells.
  • Highest measured level in the last 10 years: Combined Radium (-226 and -228), 7 pCi/L, federal limit 5 pCi/L (1.4 times the limit), 2017.
  • Record on file since 1991, with 7 health-based violations before October 19, 2016.
  • Lead pipe inventory: 0 lead and 0 unknown out of 3,658 service lines.

Check whether New Baltimore Regional serves your address

Address suggestions by Mapbox

Health-based violations

Since October 2016

Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.

Contaminant Rule family Start date Status Acute
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 7 pCi/L, federal limit 5 pCi/L (1.4 times the limit)
340 Apr 1, 2017 Resolved No

Full record since 1991

EPA's records for New Baltimore Regional go back to 1991. Before October 19, 2016 they list 7 health-based violations (4 resolved, 3 archived by EPA without a recorded fix) and 1 monitoring or reporting violation.

Violations that began in Health-based Monitoring and reporting
1990s 3 0
2000s 4 0
2010 to October 18, 2016 0 1
October 19, 2016 to 2019 1 0

Most recent health-based violation before October 19, 2016: Combined Radium (-226 and -228), began January 2002, Resolved.

Show all 7 health-based violations before October 19, 2016
Contaminant Start date Status
Combined Radium (-226 and -228)
Contaminant limit exceeded
Jan 1, 2002 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Jan 1, 2001 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Jul 1, 2000 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Apr 1, 2000 Resolved
Total Coliform
Contaminant limit exceeded
Feb 1, 1993 Archived
Total Coliform
Contaminant limit exceeded
Dec 1, 1992 Archived
Total Coliform
Contaminant limit exceeded
Feb 1, 1991 Archived

What the violations mean

Combined Radium (-226 and -228)

1 incident

Test results for Combined Radium (-226 and -228) were above the federal limit (a maximum contaminant level violation).

The utility had to notify customers about this violation.

Where the water comes from

New Baltimore Regional draws water from 13 wells.

Annual water quality report

New Baltimore Regional must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.

Where the state allows it, systems serving fewer than 10,000 people may publish the report in a local newspaper or news site instead of mailing it, and must provide a copy on request.

Find a posted report with EPA's Consumer Confidence Report search

Testing your own water

To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by Virginia.