Public water system record
Goodsprings WSC
Serves an area of Rusk County, TX · 2,541 people served
Federal records show 10 health-based violations and 2 monitoring/reporting issues for Goodsprings WSC in the last ten years. The most serious issue in this window was a resolved Total Trihalomethanes (TTHMs) violation.
System profile
- Health-based violations, last 10 years
- 10
- Resolved
- 10
- Unresolved
- 0
- Any acute record
- No
- Monitoring issues, last 10 years
- 2
Key facts
- Goodsprings WSC draws water from 6 wells.
- Highest measured level in the last 10 years: Haloacetic Acids (HAA5), 0.067 mg/L, federal limit 0.06 mg/L (1.1 times the limit), 2017.
- Most recent formal enforcement: compliance order with a penalty by Texas, May 2020.
- Record on file since 2003, with 8 health-based violations before October 19, 2016.
- Lead pipe inventory: 0 lead and 0 unknown out of 873 service lines.
Check whether Goodsprings WSC serves your address
Health-based violations
Since October 2016Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.
| Contaminant | Rule family | Start date | Status | Acute |
|---|---|---|---|---|
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
|
220 | Jul 1, 2020 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.061 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Jul 1, 2019 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.062 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Apr 1, 2019 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.062 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Jan 1, 2019 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.061 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Oct 1, 2018 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.064 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Oct 1, 2017 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.064 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Jul 1, 2017 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.067 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Apr 1, 2017 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.067 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
220 | Jan 1, 2017 | Resolved | No |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.062 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
220 | Oct 1, 2016 | Resolved | No |
Monitoring and reporting issues
Since October 2016Missed tests or reports, not contaminants found above a limit.
| Issue | Start date | Status |
|---|---|---|
|
E. coli
Monitoring and reporting
|
Aug 28, 2025 | Active |
|
Consumer Confidence Rule
OTHER
|
Jul 1, 2017 | Resolved |
Full record since 2003
EPA's records for Goodsprings WSC go back to 2003. Before October 19, 2016 they list 8 health-based violations (8 resolved) and 7 monitoring or reporting violations.
| Violations that began in | Health-based | Monitoring and reporting |
|---|---|---|
| 2000s | 0 | 1 |
| 2010 to October 18, 2016 | 8 | 6 |
| October 19, 2016 to 2019 | 8 | 1 |
| 2020s | 1 | 1 |
Most recent health-based violation before October 19, 2016: Haloacetic Acids (HAA5), began October 2016, Resolved.
Show all 8 health-based violations before October 19, 2016
| Contaminant | Start date | Status |
|---|---|---|
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.062 mg/L, federal limit 0.06 mg/L (at or just above the limit)
|
Oct 1, 2016 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.096 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
|
Apr 1, 2016 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.079 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
|
Apr 1, 2016 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.097 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
|
Jan 1, 2016 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.082 mg/L, federal limit 0.06 mg/L (1.4 times the limit)
|
Jan 1, 2016 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.063 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
Oct 1, 2015 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.064 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
Jul 1, 2015 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.083 mg/L, federal limit 0.08 mg/L (at or just above the limit)
|
Jul 1, 2014 | Resolved |
Enforcement actions
Texas regulators took 2 formal enforcement actions against Goodsprings WSC between 2017 and 2020. The most recent was a compliance order with a penalty in May 2020.
| Date | By | Action | Violations covered |
|---|---|---|---|
| May 12, 2020 | Texas | Compliance order with a penalty | 4 violations (4 health-based): Haloacetic Acids (HAA5) |
| Feb 22, 2017 | Texas | Compliance order with a penalty | 11 violations (11 health-based): Haloacetic Acids (HAA5), Total Trihalomethanes (TTHMs) |
What the violations mean
Haloacetic Acids (HAA5)
9 incidentsHaloacetic acid byproducts exceeded the federal limit
Long-term exposure to HAAs may increase cancer risk
Total Trihalomethanes (TTHMs)
1 incidentDisinfection byproduct levels exceeded the federal limit
Long-term TTHM exposure may increase bladder cancer risk
Where the water comes from
Goodsprings WSC draws water from 6 wells. It also has an emergency connection to Goodsprings WSC Plant C. 1 other public water system has an emergency connection to Goodsprings WSC.
Emergency or part-time connections to
- Goodsprings WSC Plant C Henderson, TX
Annual water quality report
Goodsprings WSC must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.
Where the state allows it, systems serving fewer than 10,000 people may publish the report in a local newspaper or news site instead of mailing it, and must provide a copy on request.
Find a posted report with EPA's Consumer Confidence Report search
Testing your own water
To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by Texas.
Certified drinking water labs by state EPA guidance for private wells