Public water system record

Tempe WSC 1

Serves an area of Polk County, TX that includes West Livingston · 2,725 people served

Federal records show 144 health-based violations and 88 monitoring/reporting issues for Tempe WSC 1 in the last ten years. The most serious issue in this window was a Arsenic violation that EPA lists as archived, not resolved.

  • TX1870105
  • LIVINGSTON
  • TX
  • 2,725 served

System profile

Source water Groundwater
ZIP 77351
EPA system ID TX1870105

Verify this system on EPA ECHO →

Health-based violations, last 10 years
144
Resolved
105
Unresolved
0
Archived by EPA
39
Any acute record
No
Monitoring issues, last 10 years
88

Key facts

  • Tempe WSC 1 draws water from 5 wells (1 of them for emergency, seasonal or other part-time use).
  • Highest measured level in the last 10 years: Gross Alpha, Excl. Radon and U, 67 pCi/L, federal limit 15 pCi/L (4.5 times the limit), 2018.
  • Most recent formal enforcement: compliance order (no penalty) by EPA, May 2017.
  • Record on file since 1993, with 156 health-based violations before October 19, 2016.
  • Lead pipe inventory: 0 lead and 902 unknown out of 903 service lines.

Check whether Tempe WSC 1 serves your address

Address suggestions by Mapbox

Health-based violations

Since October 2016

Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.

Contaminant Rule family Start date Status Acute
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Oct 1, 2025 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.016 mg/L, federal limit 0.01 mg/L (1.6 times the limit)
330 Oct 1, 2025 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Jul 1, 2025 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.016 mg/L, federal limit 0.01 mg/L (1.6 times the limit)
330 Jul 1, 2025 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
330 Apr 1, 2025 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Jan 1, 2025 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Oct 1, 2024 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.019 mg/L, federal limit 0.01 mg/L (1.9 times the limit)
330 Jul 1, 2024 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.019 mg/L, federal limit 0.01 mg/L (1.9 times the limit)
330 Apr 1, 2024 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
330 Apr 1, 2024 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Jan 1, 2024 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
330 Jan 1, 2024 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 25 pCi/L, federal limit 15 pCi/L (1.7 times the limit)
340 Oct 1, 2023 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 10 pCi/L, federal limit 5 pCi/L (2 times the limit)
340 Oct 1, 2023 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Oct 1, 2023 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Oct 1, 2023 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 13 pCi/L, federal limit 5 pCi/L (2.6 times the limit)
340 Jul 1, 2023 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 34 pCi/L, federal limit 15 pCi/L (2.3 times the limit)
340 Jul 1, 2023 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Jul 1, 2023 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Jul 1, 2023 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 44 pCi/L, federal limit 15 pCi/L (2.9 times the limit)
340 Apr 1, 2023 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 5 pCi/L (3.2 times the limit)
340 Apr 1, 2023 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Apr 1, 2023 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 46 pCi/L, federal limit 15 pCi/L (3.1 times the limit)
340 Jan 1, 2023 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 5 pCi/L (3.2 times the limit)
340 Jan 1, 2023 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Jan 1, 2023 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.019 mg/L, federal limit 0.01 mg/L (1.9 times the limit)
330 Jan 1, 2023 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 52 pCi/L, federal limit 15 pCi/L (3.5 times the limit)
340 Oct 1, 2022 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 5 pCi/L (3.2 times the limit)
340 Oct 1, 2022 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Oct 1, 2022 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.014 mg/L, federal limit 0.01 mg/L (1.4 times the limit)
330 Oct 1, 2022 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 56 pCi/L, federal limit 15 pCi/L (3.7 times the limit)
340 Jul 1, 2022 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 5 pCi/L (3.4 times the limit)
340 Jul 1, 2022 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Jul 1, 2022 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
330 Jul 1, 2022 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 5 pCi/L (3.6 times the limit)
340 Apr 1, 2022 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 60 pCi/L, federal limit 15 pCi/L (4 times the limit)
340 Apr 1, 2022 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Apr 1, 2022 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.02 mg/L, federal limit 0.01 mg/L (2 times the limit)
330 Apr 1, 2022 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 59 pCi/L, federal limit 15 pCi/L (3.9 times the limit)
340 Jan 1, 2022 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 19 pCi/L, federal limit 5 pCi/L (3.8 times the limit)
340 Jan 1, 2022 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Jan 1, 2022 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Jan 1, 2022 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 54 pCi/L, federal limit 15 pCi/L (3.6 times the limit)
340 Oct 1, 2021 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 19 pCi/L, federal limit 5 pCi/L (3.8 times the limit)
340 Oct 1, 2021 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
330 Oct 1, 2021 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Oct 1, 2021 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 52 pCi/L, federal limit 15 pCi/L (3.5 times the limit)
340 Jul 1, 2021 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 19 pCi/L, federal limit 5 pCi/L (3.8 times the limit)
340 Jul 1, 2021 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.014 mg/L, federal limit 0.01 mg/L (1.4 times the limit)
330 Jul 1, 2021 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Jul 1, 2021 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 54 pCi/L, federal limit 15 pCi/L (3.6 times the limit)
340 Apr 1, 2021 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 19 pCi/L, federal limit 5 pCi/L (3.8 times the limit)
340 Apr 1, 2021 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Apr 1, 2021 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
330 Apr 1, 2021 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 57 pCi/L, federal limit 15 pCi/L (3.8 times the limit)
340 Jan 1, 2021 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 5 pCi/L (3.6 times the limit)
340 Jan 1, 2021 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Jan 1, 2021 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Jan 1, 2021 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 59 pCi/L, federal limit 15 pCi/L (3.9 times the limit)
340 Oct 1, 2020 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 5 pCi/L (3.6 times the limit)
340 Oct 1, 2020 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Oct 1, 2020 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Oct 1, 2020 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 5 pCi/L (3.6 times the limit)
340 Jul 1, 2020 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 62 pCi/L, federal limit 15 pCi/L (4.1 times the limit)
340 Jul 1, 2020 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Jul 1, 2020 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Jul 1, 2020 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Apr 1, 2020 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 63 pCi/L, federal limit 15 pCi/L (4.2 times the limit)
340 Apr 1, 2020 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 19 pCi/L, federal limit 5 pCi/L (3.8 times the limit)
340 Apr 1, 2020 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Apr 1, 2020 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 5 pCi/L (3.6 times the limit)
340 Jan 1, 2020 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 61 pCi/L, federal limit 15 pCi/L (4.1 times the limit)
340 Jan 1, 2020 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Jan 1, 2020 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Jan 1, 2020 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 58 pCi/L, federal limit 15 pCi/L (3.9 times the limit)
340 Oct 1, 2019 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 5 pCi/L (3.6 times the limit)
340 Oct 1, 2019 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Oct 1, 2019 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
330 Oct 1, 2019 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 59 pCi/L, federal limit 15 pCi/L (3.9 times the limit)
340 Jul 1, 2019 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 5 pCi/L (3.6 times the limit)
340 Jul 1, 2019 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.015 mg/L, federal limit 0.01 mg/L (1.5 times the limit)
330 Jul 1, 2019 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Jul 1, 2019 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 58 pCi/L, federal limit 15 pCi/L (3.9 times the limit)
340 Apr 1, 2019 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 5 pCi/L (3.6 times the limit)
340 Apr 1, 2019 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Apr 1, 2019 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.015 mg/L, federal limit 0.01 mg/L (1.5 times the limit)
330 Apr 1, 2019 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 62 pCi/L, federal limit 15 pCi/L (4.1 times the limit)
340 Jan 1, 2019 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 5 pCi/L (3.4 times the limit)
340 Jan 1, 2019 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Jan 1, 2019 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.015 mg/L, federal limit 0.01 mg/L (1.5 times the limit)
330 Jan 1, 2019 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 67 pCi/L, federal limit 15 pCi/L (4.5 times the limit)
340 Oct 1, 2018 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
340 Oct 1, 2018 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 5 pCi/L (3.4 times the limit)
340 Oct 1, 2018 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.014 mg/L, federal limit 0.01 mg/L (1.4 times the limit)
330 Oct 1, 2018 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Oct 1, 2018 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 64 pCi/L, federal limit 15 pCi/L (4.3 times the limit)
340 Jul 1, 2018 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 19 pCi/L, federal limit 15 pCi/L (1.3 times the limit)
340 Jul 1, 2018 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Jul 1, 2018 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 5 pCi/L (3.2 times the limit)
340 Jul 1, 2018 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.016 mg/L, federal limit 0.01 mg/L (1.6 times the limit)
330 Jul 1, 2018 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Jul 1, 2018 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 15 pCi/L, federal limit 5 pCi/L (3 times the limit)
340 Apr 1, 2018 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Apr 1, 2018 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
340 Apr 1, 2018 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 60 pCi/L, federal limit 15 pCi/L (4 times the limit)
340 Apr 1, 2018 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Apr 1, 2018 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.016 mg/L, federal limit 0.01 mg/L (1.6 times the limit)
330 Apr 1, 2018 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
340 Jan 1, 2018 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Jan 1, 2018 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 14 pCi/L, federal limit 5 pCi/L (2.8 times the limit)
340 Jan 1, 2018 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 51 pCi/L, federal limit 15 pCi/L (3.4 times the limit)
340 Jan 1, 2018 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Jan 1, 2018 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.016 mg/L, federal limit 0.01 mg/L (1.6 times the limit)
330 Jan 1, 2018 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 13 pCi/L, federal limit 5 pCi/L (2.6 times the limit)
340 Oct 1, 2017 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 49 pCi/L, federal limit 15 pCi/L (3.3 times the limit)
340 Oct 1, 2017 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Oct 1, 2017 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
340 Oct 1, 2017 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
330 Oct 1, 2017 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Oct 1, 2017 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
340 Jul 1, 2017 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 14 pCi/L, federal limit 5 pCi/L (2.8 times the limit)
340 Jul 1, 2017 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Jul 1, 2017 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 51 pCi/L, federal limit 15 pCi/L (3.4 times the limit)
340 Jul 1, 2017 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.016 mg/L, federal limit 0.01 mg/L (1.6 times the limit)
330 Jul 1, 2017 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Jul 1, 2017 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 51 pCi/L, federal limit 15 pCi/L (3.4 times the limit)
340 Apr 1, 2017 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 15 pCi/L (1.2 times the limit)
340 Apr 1, 2017 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Apr 1, 2017 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
330 Apr 1, 2017 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Arsenic
Contaminant limit exceeded
Measured 0.011 mg/L, federal limit 0.01 mg/L (1.1 times the limit)
330 Apr 1, 2017 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 14 pCi/L, federal limit 5 pCi/L (2.8 times the limit)
340 Apr 1, 2017 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 14 pCi/L, federal limit 5 pCi/L (2.8 times the limit)
340 Jan 1, 2017 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Jan 1, 2017 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 15 pCi/L (1.2 times the limit)
340 Jan 1, 2017 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 54 pCi/L, federal limit 15 pCi/L (3.6 times the limit)
340 Jan 1, 2017 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Jan 1, 2017 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
330 Jan 1, 2017 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 14 pCi/L, federal limit 5 pCi/L (2.8 times the limit)
340 Oct 1, 2016 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 53 pCi/L, federal limit 15 pCi/L (3.5 times the limit)
340 Oct 1, 2016 Resolved No
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 19 pCi/L, federal limit 15 pCi/L (1.3 times the limit)
340 Oct 1, 2016 Resolved No
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
340 Oct 1, 2016 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
330 Oct 1, 2016 Resolved No
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
330 Oct 1, 2016 Archived
Violation period ended. EPA no longer counts it toward current compliance, but no fix was formally recorded.
No

Monitoring and reporting issues

Since October 2016

Missed tests or reports, not contaminants found above a limit.

Issue Start date Status
Public Notice
OTHER
Dec 22, 2022 Resolved
Public Notice
OTHER
Dec 22, 2022 Resolved
Public Notice
OTHER
Apr 28, 2020 Resolved
Public Notice
OTHER
Apr 28, 2020 Resolved
Public Notice
OTHER
Apr 16, 2020 Resolved
Public Notice
OTHER
Apr 16, 2020 Resolved
Public Notice
OTHER
Dec 12, 2019 Resolved
Public Notice
OTHER
Dec 12, 2019 Resolved
Public Notice
OTHER
Oct 24, 2019 Resolved
Public Notice
OTHER
Oct 24, 2019 Resolved
Public Notice
OTHER
Oct 9, 2019 Resolved
Public Notice
OTHER
Sep 18, 2019 Resolved
Public Notice
OTHER
May 2, 2019 Resolved
Public Notice
OTHER
Apr 16, 2019 Resolved
Public Notice
OTHER
Jan 29, 2019 Resolved
Public Notice
OTHER
Jan 29, 2019 Resolved
Lead and Copper Rule
Monitoring and reporting
Dec 30, 2018 Resolved
Public Notice
OTHER
Dec 28, 2018 Resolved
Public Notice
OTHER
Dec 28, 2018 Resolved
Public Notice
OTHER
Dec 28, 2018 Resolved
Public Notice
OTHER
Dec 28, 2018 Resolved
Public Notice
OTHER
Oct 25, 2018 Resolved
Public Notice
OTHER
Sep 26, 2018 Resolved
Public Notice
OTHER
Sep 26, 2018 Resolved
Public Notice
OTHER
Sep 26, 2018 Resolved
Public Notice
OTHER
Sep 26, 2018 Resolved
Public Notice
OTHER
Sep 26, 2018 Resolved
Public Notice
OTHER
Sep 26, 2018 Resolved
Public Notice
OTHER
Jul 11, 2018 Resolved
Public Notice
OTHER
Jul 11, 2018 Resolved
Public Notice
OTHER
Mar 14, 2018 Resolved
Public Notice
OTHER
Mar 14, 2018 Resolved
Public Notice
OTHER
Mar 14, 2018 Resolved
Public Notice
OTHER
Mar 14, 2018 Resolved
Public Notice
OTHER
Mar 14, 2018 Resolved
Public Notice
OTHER
Mar 8, 2018 Resolved
Public Notice
OTHER
Jan 15, 2018 Resolved
Public Notice
OTHER
Oct 26, 2017 Resolved
Public Notice
OTHER
Oct 13, 2017 Resolved
Lead and Copper Rule
Monitoring and reporting
Oct 1, 2017 Resolved
Public Notice
OTHER
Sep 4, 2017 Resolved
Public Notice
OTHER
Aug 25, 2017 Resolved
Public Notice
OTHER
Aug 25, 2017 Resolved
Public Notice
OTHER
Aug 25, 2017 Resolved
Public Notice
OTHER
Aug 25, 2017 Resolved
Public Notice
OTHER
Jun 30, 2017 Resolved
Public Notice
OTHER
Jun 30, 2017 Resolved
Public Notice
OTHER
May 4, 2017 Resolved
Public Notice
OTHER
May 4, 2017 Resolved
Public Notice
OTHER
May 4, 2017 Resolved
Public Notice
OTHER
May 4, 2017 Resolved
Public Notice
OTHER
Apr 11, 2017 Resolved
Public Notice
OTHER
Apr 11, 2017 Resolved
Public Notice
OTHER
Feb 7, 2017 Resolved
Public Notice
OTHER
Feb 7, 2017 Resolved
Public Notice
OTHER
Feb 7, 2017 Resolved
Public Notice
OTHER
Jan 23, 2017 Resolved
Public Notice
OTHER
Jan 23, 2017 Resolved
Public Notice
OTHER
Jan 2, 2017 Resolved
Public Notice
OTHER
Dec 28, 2016 Resolved
Public Notice
OTHER
Dec 19, 2016 Resolved
Public Notice
OTHER
Oct 21, 2016 Resolved
Public Notice
OTHER
Oct 21, 2016 Resolved
Public Notice
OTHER
Jul 7, 2016 Resolved
Public Notice
OTHER
Jul 7, 2016 Resolved
Consumer Confidence Rule
OTHER
Jul 1, 2016 Resolved
Public Notice
OTHER
Apr 25, 2016 Resolved
Public Notice
OTHER
Apr 25, 2016 Resolved
Public Notice
OTHER
Jan 15, 2016 Resolved
Consumer Confidence Rule
OTHER
Jul 1, 2015 Resolved
Public Notice
OTHER
May 12, 2015 Resolved
Public Notice
OTHER
Feb 24, 2015 Resolved
Public Notice
OTHER
Jan 14, 2015 Resolved
Public Notice
OTHER
Nov 20, 2012 Resolved
Public Notice
OTHER
Jun 27, 2012 Resolved
Public Notice
OTHER
Jun 27, 2012 Resolved
Public Notice
OTHER
Jun 27, 2012 Resolved
Public Notice
OTHER
Jun 27, 2012 Resolved
Public Notice
OTHER
Jun 27, 2012 Resolved
Public Notice
OTHER
Mar 27, 2012 Resolved
Public Notice
OTHER
Mar 27, 2012 Resolved
Public Notice
OTHER
Mar 27, 2012 Resolved
Public Notice
OTHER
Mar 27, 2012 Resolved
Public Notice
OTHER
Dec 14, 2011 Resolved
Public Notice
OTHER
Nov 17, 2011 Resolved
Public Notice
OTHER
Nov 17, 2011 Resolved
Public Notice
OTHER
Nov 17, 2011 Resolved
Public Notice
OTHER
Nov 17, 2011 Resolved

Full record since 1993

EPA's records for Tempe WSC 1 go back to 1993. Before October 19, 2016 they list 156 health-based violations (121 resolved, 35 archived by EPA without a recorded fix) and 64 monitoring or reporting violations.

Violations that began in Health-based Monitoring and reporting
1990s 2 2
2000s 44 4
2010 to October 18, 2016 110 58
October 19, 2016 to 2019 63 57
2020s 75 6

Most recent health-based violation before October 19, 2016: Combined Radium (-226 and -228), began October 2016, Resolved.

Show all 156 health-based violations before October 19, 2016
Contaminant Start date Status
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 14 pCi/L, federal limit 5 pCi/L (2.8 times the limit)
Oct 1, 2016 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 53 pCi/L, federal limit 15 pCi/L (3.5 times the limit)
Oct 1, 2016 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 19 pCi/L, federal limit 15 pCi/L (1.3 times the limit)
Oct 1, 2016 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 6 pCi/L, federal limit 5 pCi/L (1.2 times the limit)
Oct 1, 2016 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
Oct 1, 2016 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
Oct 1, 2016 Archived
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 50 pCi/L, federal limit 15 pCi/L (3.3 times the limit)
Jul 1, 2016 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
Jul 1, 2016 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 15 pCi/L, federal limit 5 pCi/L (3 times the limit)
Jul 1, 2016 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
Jul 1, 2016 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
Jul 1, 2016 Archived
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
Apr 1, 2016 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 48 pCi/L, federal limit 15 pCi/L (3.2 times the limit)
Apr 1, 2016 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 5 pCi/L (3.2 times the limit)
Apr 1, 2016 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
Apr 1, 2016 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
Apr 1, 2016 Archived
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 5 pCi/L (3.2 times the limit)
Jan 1, 2016 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 46 pCi/L, federal limit 15 pCi/L (3.1 times the limit)
Jan 1, 2016 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.017 mg/L, federal limit 0.01 mg/L (1.7 times the limit)
Jan 1, 2016 Archived
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
Jan 1, 2016 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 45 pCi/L, federal limit 15 pCi/L (3 times the limit)
Oct 1, 2015 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 15 pCi/L, federal limit 5 pCi/L (3 times the limit)
Oct 1, 2015 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
Oct 1, 2015 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.015 mg/L, federal limit 0.01 mg/L (1.5 times the limit)
Oct 1, 2015 Archived
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 14 pCi/L, federal limit 5 pCi/L (2.8 times the limit)
Jul 1, 2015 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 44 pCi/L, federal limit 15 pCi/L (2.9 times the limit)
Jul 1, 2015 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
Jul 1, 2015 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 14 pCi/L, federal limit 5 pCi/L (2.8 times the limit)
Apr 1, 2015 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 45 pCi/L, federal limit 15 pCi/L (3 times the limit)
Apr 1, 2015 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.015 mg/L, federal limit 0.01 mg/L (1.5 times the limit)
Apr 1, 2015 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 15 pCi/L, federal limit 5 pCi/L (3 times the limit)
Jan 1, 2015 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 43 pCi/L, federal limit 15 pCi/L (2.9 times the limit)
Jan 1, 2015 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.015 mg/L, federal limit 0.01 mg/L (1.5 times the limit)
Jan 1, 2015 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 5 pCi/L (3.2 times the limit)
Oct 1, 2014 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 48 pCi/L, federal limit 15 pCi/L (3.2 times the limit)
Oct 1, 2014 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.014 mg/L, federal limit 0.01 mg/L (1.4 times the limit)
Oct 1, 2014 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 54 pCi/L, federal limit 15 pCi/L (3.6 times the limit)
Jul 1, 2014 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.014 mg/L, federal limit 0.01 mg/L (1.4 times the limit)
Jul 1, 2014 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 58 pCi/L, federal limit 15 pCi/L (3.9 times the limit)
Apr 1, 2014 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 5 pCi/L (3.4 times the limit)
Apr 1, 2014 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
Apr 1, 2014 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.013 mg/L, federal limit 0.01 mg/L (1.3 times the limit)
Apr 1, 2014 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 60 pCi/L, federal limit 15 pCi/L (4 times the limit)
Jan 1, 2014 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 5 pCi/L (3.4 times the limit)
Jan 1, 2014 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.015 mg/L, federal limit 0.01 mg/L (1.5 times the limit)
Jan 1, 2014 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
Jan 1, 2014 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 60 pCi/L, federal limit 15 pCi/L (4 times the limit)
Oct 1, 2013 Resolved
Combined Radium (-226 and -228)
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 5 pCi/L (3.4 times the limit)
Oct 1, 2013 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.012 mg/L, federal limit 0.01 mg/L (1.2 times the limit)
Oct 1, 2013 Resolved
Arsenic
Contaminant limit exceeded
Measured 0.018 mg/L, federal limit 0.01 mg/L (1.8 times the limit)
Oct 1, 2013 Resolved

106 older violations are not listed here. EPA ECHO has the complete list.

Enforcement actions

Texas regulators and EPA took 5 formal enforcement actions against Tempe WSC 1 between 2007 and 2017. The most recent was a compliance order (no penalty) in May 2017.

Date By Action Violations covered
May 7, 2017 EPA Compliance order (no penalty) 398 violations (291 health-based): Arsenic, Gross Alpha, Excl. Radon and U, Combined Radium (-226 and -228), Public Notice, Lead and Copper Rule
Sep 1, 2016 EPA Compliance order (no penalty) 34 violations (16 health-based): Gross Alpha, Excl. Radon and U, Arsenic, Combined Radium (-226 and -228), Public Notice
Mar 22, 2012 EPA Compliance order (no penalty) 135 violations (118 health-based): Combined Radium (-226 and -228), Gross Alpha, Excl. Radon and U, Arsenic, Public Notice, Combined Uranium
Apr 16, 2008 Texas Signed compliance agreement 25 violations (25 health-based): Arsenic
Oct 25, 2007 Texas Signed compliance agreement 38 violations (36 health-based): Combined Radium (-226 and -228), Gross Alpha, Excl. Radon and U

What the violations mean

Arsenic

69 incidents

Arsenic exceeded the federal limit

Long-term arsenic exposure is linked to cancer and cardiovascular effects

Gross Alpha, Excl. Radon and U

38 incidents

Test results for Gross Alpha, Excl. Radon and U were above the federal limit (a maximum contaminant level violation).

The utility had to notify customers about each of these violations.

Combined Radium (-226 and -228)

37 incidents

Test results for Combined Radium (-226 and -228) were above the federal limit (a maximum contaminant level violation).

The utility had to notify customers about each of these violations.

Where the water comes from

Tempe WSC 1 draws water from 5 wells (1 of them for emergency, seasonal or other part-time use).

Annual water quality report

Tempe WSC 1 must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.

Where the state allows it, systems serving fewer than 10,000 people may publish the report in a local newspaper or news site instead of mailing it, and must provide a copy on request.

Find a posted report with EPA's Consumer Confidence Report search

Testing your own water

To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by Texas.