Public water system record

Mayaguez

Serves an area of Mayagüez Municipio and Añasco Municipio, PR that includes Mayagüez and Añasco · 151,555 people served

Federal records show 7 health-based violations and 122 monitoring/reporting issues for Mayaguez in the last ten years. The most serious issue in this window was a resolved Interim Enhanced Surface Water Treatment Rule violation.

  • PR0003283
  • MAYAGUEZ
  • PR
  • 151,555 served

System profile

Source water Surface water
ZIP 00680
EPA system ID PR0003283

Verify this system on EPA ECHO →

Health-based violations, last 10 years
7
Resolved
7
Unresolved
0
Any acute record
Yes
Monitoring issues, last 10 years
122

Key facts

  • Mayaguez draws water from 14 wells and 2 surface water intakes (2 of them for emergency, seasonal or other part-time use).
  • Highest measured level in the last 10 years: Total Trihalomethanes (TTHMs), 0.094 mg/L, federal limit 0.08 mg/L (1.2 times the limit), 2016.
  • Most recent formal enforcement: civil case filed in court by Puerto Rico, October 2018.
  • Record on file since 1980, with 102 health-based violations before October 19, 2016.
  • Lead pipe inventory: 0 lead and 24,472 unknown out of 68,868 service lines.

Check whether Mayaguez serves your address

Address suggestions by Mapbox

Health-based violations

Since October 2016

Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.

Contaminant Rule family Start date Status Acute
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
120 Sep 1, 2022 Resolved Yes
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
220 Oct 1, 2018 Resolved No
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
120 May 16, 2018 Resolved No
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
120 Jun 1, 2017 Resolved Yes
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
120 Jun 1, 2017 Resolved Yes
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
220 Jan 1, 2017 Resolved No
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.094 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
220 Oct 1, 2016 Resolved No

Monitoring and reporting issues

Since October 2016

Missed tests or reports, not contaminants found above a limit.

Issue Start date Status
Selenium
Monitoring and reporting
Jan 1, 2022 Resolved
Thallium, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Beryllium, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Antimony, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Mercury
Monitoring and reporting
Jan 1, 2022 Resolved
CYANIDE
Monitoring and reporting
Jan 1, 2022 Resolved
Chromium (total)
Monitoring and reporting
Jan 1, 2022 Resolved
Cadmium
Monitoring and reporting
Jan 1, 2022 Resolved
Barium
Monitoring and reporting
Jan 1, 2022 Resolved
Arsenic
Monitoring and reporting
Jan 1, 2022 Resolved
Selenium
Monitoring and reporting
Jan 1, 2022 Resolved
Thallium, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Beryllium, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Antimony, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Mercury
Monitoring and reporting
Jan 1, 2022 Resolved
CYANIDE
Monitoring and reporting
Jan 1, 2022 Resolved
Chromium (total)
Monitoring and reporting
Jan 1, 2022 Resolved
Cadmium
Monitoring and reporting
Jan 1, 2022 Resolved
Barium
Monitoring and reporting
Jan 1, 2022 Resolved
Arsenic
Monitoring and reporting
Jan 1, 2022 Resolved
Selenium
Monitoring and reporting
Jan 1, 2022 Resolved
Thallium, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Beryllium, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Antimony, Total
Monitoring and reporting
Jan 1, 2022 Resolved
Mercury
Monitoring and reporting
Jan 1, 2022 Resolved
CYANIDE
Monitoring and reporting
Jan 1, 2022 Resolved
Chromium (total)
Monitoring and reporting
Jan 1, 2022 Resolved
Cadmium
Monitoring and reporting
Jan 1, 2022 Resolved
Barium
Monitoring and reporting
Jan 1, 2022 Resolved
Arsenic
Monitoring and reporting
Jan 1, 2022 Resolved
ETHYLENE DIBROMIDE
Monitoring and reporting
Jan 1, 2021 Resolved
1,2-DIBROMO-3-CHLOROPROPANE
Monitoring and reporting
Jan 1, 2021 Resolved
ETHYLENE DIBROMIDE
Monitoring and reporting
Oct 1, 2020 Resolved
1,2-DIBROMO-3-CHLOROPROPANE
Monitoring and reporting
Oct 1, 2020 Resolved
Consumer Confidence Rule
OTHER
Jul 1, 2020 Resolved
Nitrite
Monitoring and reporting
Jan 1, 2020 Resolved
Methoxychlor
Monitoring and reporting
Apr 1, 2019 Resolved
Hexachlorocyclopentadiene
Monitoring and reporting
Apr 1, 2019 Resolved
HEXACHLOROBENZENE
Monitoring and reporting
Apr 1, 2019 Resolved
Heptachlor epoxide
Monitoring and reporting
Apr 1, 2019 Resolved
Heptachlor
Monitoring and reporting
Apr 1, 2019 Resolved
Endrin
Monitoring and reporting
Apr 1, 2019 Resolved
BHC-GAMMA
Monitoring and reporting
Apr 1, 2019 Resolved
Consumer Confidence Rule
OTHER
Oct 1, 2018 Resolved
Chlordane
Monitoring and reporting
Jul 31, 2018 Resolved
ETHYLENE DIBROMIDE
Monitoring and reporting
Jul 31, 2018 Resolved
1,2-DIBROMO-3-CHLOROPROPANE
Monitoring and reporting
Jul 31, 2018 Resolved
Total Polychlorinated Biphenyls (PCB)
Monitoring and reporting
Jul 31, 2018 Resolved
Pentachlorophenol
Monitoring and reporting
Jul 31, 2018 Resolved
Benzo(a)pyrene
Monitoring and reporting
Jul 31, 2018 Resolved
HEXACHLOROBENZENE
Monitoring and reporting
Jul 31, 2018 Resolved
2,4,5-TP
Monitoring and reporting
Jul 31, 2018 Resolved
2,4-D
Monitoring and reporting
Jul 31, 2018 Resolved
Heptachlor epoxide
Monitoring and reporting
Jul 31, 2018 Resolved
Heptachlor
Monitoring and reporting
Jul 31, 2018 Resolved
LASSO
Monitoring and reporting
Jul 31, 2018 Resolved
Atrazine
Monitoring and reporting
Jul 31, 2018 Resolved
Carbofuran
Monitoring and reporting
Jul 31, 2018 Resolved
Hexachlorocyclopentadiene
Monitoring and reporting
Jul 31, 2018 Resolved
Dinoseb
Monitoring and reporting
Jul 31, 2018 Resolved
Picloram
Monitoring and reporting
Jul 31, 2018 Resolved
Di(2-ethylhexyl) phthalate
Monitoring and reporting
Jul 31, 2018 Resolved
Simazine
Monitoring and reporting
Jul 31, 2018 Resolved
OXAMYL
Monitoring and reporting
Jul 31, 2018 Resolved
Di(2-ethylhexyl) adipate
Monitoring and reporting
Jul 31, 2018 Resolved
Glyphosate
Monitoring and reporting
Jul 31, 2018 Resolved
Endothall
Monitoring and reporting
Jul 31, 2018 Resolved
Diquat
Monitoring and reporting
Jul 31, 2018 Resolved
Dalapon
Monitoring and reporting
Jul 31, 2018 Resolved
Toxaphene
Monitoring and reporting
Jul 31, 2018 Resolved
Methoxychlor
Monitoring and reporting
Jul 31, 2018 Resolved
BHC-GAMMA
Monitoring and reporting
Jul 31, 2018 Resolved
Endrin
Monitoring and reporting
Jul 31, 2018 Resolved
Haloacetic Acids (HAA5)
Monitoring and reporting
Apr 1, 2018 Resolved
Total Trihalomethanes (TTHMs)
Monitoring and reporting
Apr 1, 2018 Resolved
E. coli
Monitoring and reporting
Aug 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Aug 1, 2017 Resolved
Turbidity
Monitoring and reporting
Aug 1, 2017 Resolved
E. coli
Monitoring and reporting
Aug 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Aug 1, 2017 Resolved
Turbidity
Monitoring and reporting
Aug 1, 2017 Resolved
E. coli
Monitoring and reporting
Jul 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Jul 1, 2017 Resolved
Turbidity
Monitoring and reporting
Jul 1, 2017 Resolved
E. coli
Monitoring and reporting
Jul 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Jul 1, 2017 Resolved
Turbidity
Monitoring and reporting
Jul 1, 2017 Resolved
E. coli
Monitoring and reporting
Jun 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Jun 1, 2017 Resolved
Turbidity
Monitoring and reporting
Jun 1, 2017 Resolved
E. coli
Monitoring and reporting
Jun 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Jun 1, 2017 Resolved
Turbidity
Monitoring and reporting
Jun 1, 2017 Resolved
E. coli
Monitoring and reporting
May 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
May 1, 2017 Resolved
Turbidity
Monitoring and reporting
May 1, 2017 Resolved
E. coli
Monitoring and reporting
May 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
May 1, 2017 Resolved
Turbidity
Monitoring and reporting
May 1, 2017 Resolved
E. coli
Monitoring and reporting
Apr 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Apr 1, 2017 Resolved
Turbidity
Monitoring and reporting
Apr 1, 2017 Resolved
E. coli
Monitoring and reporting
Mar 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Mar 1, 2017 Resolved
Turbidity
Monitoring and reporting
Mar 1, 2017 Resolved
E. coli
Monitoring and reporting
Mar 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Mar 1, 2017 Resolved
Turbidity
Monitoring and reporting
Mar 1, 2017 Resolved
E. coli
Monitoring and reporting
Feb 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Feb 1, 2017 Resolved
Turbidity
Monitoring and reporting
Feb 1, 2017 Resolved
E. coli
Monitoring and reporting
Feb 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Feb 1, 2017 Resolved
Turbidity
Monitoring and reporting
Feb 1, 2017 Resolved
E. coli
Monitoring and reporting
Jan 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Jan 1, 2017 Resolved
Turbidity
Monitoring and reporting
Jan 1, 2017 Resolved
E. coli
Monitoring and reporting
Jan 1, 2017 Resolved
Cryptosporidium
Monitoring and reporting
Jan 1, 2017 Resolved
Turbidity
Monitoring and reporting
Jan 1, 2017 Resolved
Lead and Copper Rule
Monitoring and reporting
Jan 1, 2016 Resolved
Lead and Copper Rule
Monitoring and reporting
Jul 1, 2012 Resolved

Full record since 1980

EPA's records for Mayaguez go back to 1980. Before October 19, 2016 they list 102 health-based violations (42 resolved, 60 archived by EPA without a recorded fix) and 562 monitoring or reporting violations.

Violations that began in Health-based Monitoring and reporting
1980s 0 18
1990s 48 8
2000s 16 398
2010 to October 18, 2016 38 138
October 19, 2016 to 2019 5 84
2020s 1 36

Most recent health-based violation before October 19, 2016: Total Trihalomethanes (TTHMs), began October 2016, Resolved.

Show all 102 health-based violations before October 19, 2016
Contaminant Start date Status
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.094 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Oct 1, 2016 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.106 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Jul 1, 2016 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.068 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
Jul 1, 2016 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.066 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
Apr 1, 2016 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.097 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Apr 1, 2016 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.103 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Jan 1, 2016 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.07 mg/L, federal limit 0.06 mg/L (1.2 times the limit)
Jan 1, 2016 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.093 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Oct 1, 2015 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.083 mg/L, federal limit 0.08 mg/L (at or just above the limit)
Jul 1, 2015 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.087 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
Apr 1, 2015 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.092 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Jan 1, 2015 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.072 mg/L, federal limit 0.06 mg/L (1.2 times the limit)
Jan 1, 2015 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.085 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
Oct 1, 2014 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.07 mg/L, federal limit 0.06 mg/L (1.2 times the limit)
Oct 1, 2014 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.073 mg/L, federal limit 0.06 mg/L (1.2 times the limit)
Jul 1, 2014 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.086 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
Jul 1, 2014 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.077 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
Apr 1, 2014 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.076 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
Jan 1, 2014 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.076 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
Oct 1, 2013 Resolved
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.076 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
Jul 1, 2013 Archived
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.072 mg/L, federal limit 0.06 mg/L (1.2 times the limit)
Apr 1, 2013 Archived
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.061 mg/L, federal limit 0.06 mg/L (at or just above the limit)
Jan 1, 2013 Archived
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Oct 1, 2011 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Jul 1, 2011 Resolved
Total Coliform (acute)
Contaminant limit exceeded
Jun 1, 2011 Resolved
CARBON, TOTAL
Treatment technique failure
Apr 1, 2011 Resolved
CARBON, TOTAL
Treatment technique failure
Jan 1, 2011 Resolved
CARBON, TOTAL
Treatment technique failure
Oct 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Oct 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Oct 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Sep 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Aug 1, 2010 Resolved
CARBON, TOTAL
Treatment technique failure
Jul 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Jul 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Jun 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
May 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
May 1, 2010 Resolved
CARBON, TOTAL
Treatment technique failure
Apr 1, 2010 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Dec 1, 2009 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Nov 1, 2009 Resolved
Total Coliform (acute)
Contaminant limit exceeded
Oct 1, 2009 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Oct 1, 2009 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Sep 1, 2009 Resolved
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Aug 1, 2009 Resolved
CARBON, TOTAL
Treatment technique failure
Oct 1, 2005 Archived
CARBON, TOTAL
Treatment technique failure
Oct 1, 2005 Resolved
CARBON, TOTAL
Treatment technique failure
Jul 1, 2005 Archived
CARBON, TOTAL
Treatment technique failure
Apr 1, 2005 Archived
CARBON, TOTAL
Treatment technique failure
Jan 1, 2005 Archived
Interim Enhanced Surface Water Treatment Rule (acute)
Treatment technique failure
Oct 1, 2004 Archived

52 older violations are not listed here. EPA ECHO has the complete list.

Enforcement actions

Puerto Rico regulators took 10 formal enforcement actions against Mayaguez between 1998 and 2018, filed as 14 records in EPA's data. The most recent was a civil case filed in court in October 2018.

Date By Action Violations covered
Oct 30, 2018 Puerto Rico Civil case filed in court 1 violation (1 health-based): Total Trihalomethanes (TTHMs)
Sep 19, 2016 Puerto Rico Civil case filed in court 1 violation (1 health-based): Total Trihalomethanes (TTHMs)
Apr 14, 2016 Puerto Rico Civil case filed in court 2 violations (2 health-based): Haloacetic Acids (HAA5)
Aug 3, 2015 Puerto Rico Civil case filed in court 1 violation (1 health-based): Total Trihalomethanes (TTHMs)
Nov 5, 2014 Puerto Rico Civil case filed in court 8 violations (8 health-based): Total Trihalomethanes (TTHMs)
Jul 17, 2013 Puerto Rico Compliance order (no penalty) 21 violations: 1,2,4-Trichlorobenzene, Xylenes, Total, DICHLOROMETHANE, p-Dichlorobenzene, Vinyl chloride
Apr 30, 2013 Puerto Rico Civil case filed in court 17 violations (17 health-based): Total Trihalomethanes (TTHMs), Haloacetic Acids (HAA5)
Jun 2, 2010 Puerto Rico Civil case filed in court 5 violations (5 health-based): Interim Enhanced Surface Water Treatment Rule
Jun 24, 2008 Puerto Rico Civil case filed in court 12 violations (12 health-based): CARBON, TOTAL, Interim Enhanced Surface Water Treatment Rule
Jun 30, 1998 Puerto Rico Compliance order with a penalty 51 violations (46 health-based): Surface Water Treatment Rule

What the violations mean

Interim Enhanced Surface Water Treatment Rule

3 incidents

The system did not meet a filtration or treatment requirement for surface water

Inadequate treatment of surface water can let pathogens such as Cryptosporidium and Giardia through

Total Trihalomethanes (TTHMs)

3 incidents

Disinfection byproduct levels exceeded the federal limit

Long-term TTHM exposure may increase bladder cancer risk

Long Term 2 Enhanced Surface Water Treatment Rule

1 incident

The system failed required surface water treatment or filtration standards

Untreated or inadequately treated surface water can contain bacteria and viruses

Where the water comes from

Mayaguez draws water from 14 wells and 2 surface water intakes (2 of them for emergency, seasonal or other part-time use).

Annual water quality report

Mayaguez must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.

Systems serving 10,000 or more people must mail or deliver the report to every customer, and from 2027 they must send it twice a year.

Find a posted report with EPA's Consumer Confidence Report search

Testing your own water

To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by Puerto Rico.