Public water system record

Patton Boro Water Dept

Serves Patton, Cambria County, PA · 1,805 people served

Federal records show 3 health-based violations and 13 monitoring/reporting issues for Patton Boro Water Dept in the last ten years. The most serious issue in this window was a resolved Groundwater Rule violation.

  • PA4110024
  • PATTON
  • PA
  • 1,805 served

System profile

Source water Groundwater
ZIP 16668
EPA system ID PA4110024

Verify this system on EPA ECHO →

Health-based violations, last 10 years
3
Resolved
3
Unresolved
0
Any acute record
No
Monitoring issues, last 10 years
13

Key facts

  • Patton Boro Water Dept draws water from 2 wells.
  • Most recent formal enforcement: signed compliance agreement by Pennsylvania, September 2012.
  • Record on file since 1982, with 40 health-based violations before October 19, 2016.
  • Lead pipe inventory: 0 lead and 71 unknown out of 980 service lines.

Check whether Patton Boro Water Dept serves your address

Address suggestions by Mapbox

Health-based violations

Since October 2016

Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.

Contaminant Rule family Start date Status Acute
Groundwater Rule
Treatment technique failure
140 Jul 1, 2019 Resolved No
Groundwater Rule
Treatment technique failure
140 Aug 1, 2017 Resolved No
Groundwater Rule
Treatment technique failure
140 Jul 1, 2017 Resolved No

Monitoring and reporting issues

Since October 2016

Missed tests or reports, not contaminants found above a limit.

Issue Start date Status
Public Notice
OTHER
Oct 11, 2024 Resolved
Public Notice
OTHER
Oct 11, 2024 Resolved
Groundwater Rule
Monitoring and reporting
Sep 1, 2024 Resolved
Total Trihalomethanes (TTHMs)
Monitoring and reporting
Jul 1, 2023 Resolved
Haloacetic Acids (HAA5)
Monitoring and reporting
Jul 1, 2023 Resolved
Groundwater Rule
Monitoring and reporting
Sep 1, 2021 Resolved
Groundwater Rule
Monitoring and reporting
Jul 1, 2021 Resolved
Mercury
Monitoring and reporting
Jan 1, 2021 Resolved
Public Notice
OTHER
Jul 13, 2019 Resolved
Chlorine
Monitoring and reporting
Jul 1, 2019 Resolved
Public Notice
OTHER
Aug 13, 2017 Resolved
Public Notice
OTHER
Jul 13, 2017 Resolved
Total Trihalomethanes (TTHMs)
Monitoring and reporting
Oct 1, 2016 Resolved

Full record since 1982

EPA's records for Patton Boro Water Dept go back to 1982. Before October 19, 2016 they list 40 health-based violations (40 resolved) and 111 monitoring or reporting violations.

Violations that began in Health-based Monitoring and reporting
1980s 0 32
1990s 10 41
2000s 8 12
2010 to October 18, 2016 22 26
October 19, 2016 to 2019 3 4
2020s 0 8

Most recent health-based violation before October 19, 2016: Total Trihalomethanes (TTHMs), began April 2016, Resolved.

Show all 40 health-based violations before October 19, 2016
Contaminant Start date Status
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Apr 1, 2016 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Oct 1, 2015 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Jul 1, 2015 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.0935 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Jul 1, 2014 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.0955 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Apr 1, 2014 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.09575 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Jan 1, 2014 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.09525 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Oct 1, 2013 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.104 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Jul 1, 2013 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.103 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Apr 1, 2013 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.10525 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Jan 1, 2013 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.109025 mg/L, federal limit 0.08 mg/L (1.4 times the limit)
Oct 1, 2012 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.096775 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Jul 1, 2012 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.098025 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Apr 1, 2012 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.09355 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Jan 1, 2012 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.088975 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
Oct 1, 2011 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.0878 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
Jul 1, 2011 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.10255 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Apr 1, 2011 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.105275 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Jan 1, 2011 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.110875 mg/L, federal limit 0.08 mg/L (1.4 times the limit)
Oct 1, 2010 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.11705 mg/L, federal limit 0.08 mg/L (1.5 times the limit)
Jul 1, 2010 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.10655 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Apr 1, 2010 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.103775 mg/L, federal limit 0.08 mg/L (1.3 times the limit)
Jan 1, 2010 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.10865 mg/L, federal limit 0.08 mg/L (1.4 times the limit)
Jul 1, 2009 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.0994 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Apr 1, 2009 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.095133 mg/L, federal limit 0.08 mg/L (1.2 times the limit)
Jan 1, 2009 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081492 mg/L, federal limit 0.08 mg/L (at or just above the limit)
Jul 1, 2008 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.083575 mg/L, federal limit 0.08 mg/L (at or just above the limit)
Apr 1, 2008 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.084267 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
Jan 1, 2008 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Jan 1, 2006 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Oct 1, 2005 Resolved
Surface Water Treatment Rule
Treatment technique failure
Sep 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Aug 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jul 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Mar 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Aug 1, 1992 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jul 1, 1992 Resolved
Surface Water Treatment Rule
Treatment technique failure
Dec 1, 1991 Resolved
Surface Water Treatment Rule
Treatment technique failure
Oct 1, 1991 Resolved
Surface Water Treatment Rule
Treatment technique failure
Mar 1, 1991 Resolved
Surface Water Treatment Rule
Treatment technique failure
Dec 1, 1990 Resolved

Enforcement actions

Pennsylvania regulators took 6 formal enforcement actions against Patton Boro Water Dept and issued 2 boil water orders between 1991 and 2012, filed as 9 records in EPA's data. The most recent was a signed compliance agreement in September 2012.

Date By Action Violations covered
Sep 6, 2012 Pennsylvania Signed compliance agreement 2 violations (2 health-based): Total Trihalomethanes (TTHMs)
Mar 14, 2011 Pennsylvania Compliance order (no penalty) 2 violations (2 health-based): Total Trihalomethanes (TTHMs)
Mar 21, 2006 Pennsylvania Consent decree or court judgment 4 violations (1 health-based): Surface Water Treatment Rule, Public Notice, Endothall, Total Trihalomethanes (TTHMs)
Feb 28, 2006 Pennsylvania Consent decree or court judgment 1 violation: Total Coliform
Mar 15, 2004 Pennsylvania Consent decree or court judgment 1 violation: Surface Water Treatment Rule
Mar 29, 1993 Pennsylvania Boil water order 1 violation (1 health-based): Surface Water Treatment Rule
Dec 5, 1991 Pennsylvania Signed compliance agreement 2 violations (2 health-based): Surface Water Treatment Rule
Oct 23, 1991 Pennsylvania Boil water order 1 violation (1 health-based): Surface Water Treatment Rule

What the violations mean

Groundwater Rule

3 incidents

The system did not complete a treatment step or action that the Groundwater Rule requires (a treatment technique violation).

The utility had to notify customers about each of these violations.

Where the water comes from

Patton Boro Water Dept draws water from 2 wells. 1 other community water system buys water from Patton Boro Water Dept.

Community systems that buy water from it

Annual water quality report

Patton Boro Water Dept must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.

Where the state allows it, systems serving fewer than 10,000 people may publish the report in a local newspaper or news site instead of mailing it, and must provide a copy on request.

Find a posted report with EPA's Consumer Confidence Report search

Testing your own water