Public water system record

Cadiz Village PWS

Serves Cadiz, Harrison County, OH · 3,353 people served

Federal records show 7 health-based violations and 4 monitoring/reporting issues for Cadiz Village PWS in the last ten years. The most serious issue in this window was a resolved Interim Enhanced Surface Water Treatment Rule violation.

  • OH3400214
  • CADIZ
  • OH
  • 3,353 served

System profile

Source water Surface water
ZIP 43907
EPA system ID OH3400214

Verify this system on EPA ECHO →

Health-based violations, last 10 years
7
Resolved
7
Unresolved
0
Any acute record
Yes
Monitoring issues, last 10 years
4

Key facts

  • Cadiz Village PWS draws water from 1 surface water intake.
  • Most recent enforcement action: boil water order by Ohio, June 2025.
  • Record on file since 1988, with 42 health-based violations before October 19, 2016.

Check whether Cadiz Village PWS serves your address

Address suggestions by Mapbox

Health-based violations

Since October 2016

Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.

Contaminant Rule family Start date Status Acute
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
120 Sep 1, 2025 Resolved Yes
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
120 Aug 1, 2025 Resolved Yes
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
120 Jul 1, 2025 Resolved Yes
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
120 Jun 1, 2025 Resolved Yes
LEAD AND COPPER RULE REVISIONS
Treatment technique failure
350 Oct 17, 2024 Resolved No
Stage 1 Disinfection Byproducts Rule
Treatment technique failure
210 Jun 3, 2024 Resolved No
Interim Enhanced Surface Water Treatment Rule
Treatment technique failure
120 Jan 1, 2018 Resolved Yes

Monitoring and reporting issues

Since October 2016

Missed tests or reports, not contaminants found above a limit.

Issue Start date Status
Public Notice
OTHER
Oct 20, 2025 Resolved
LEAD AND COPPER RULE REVISIONS
RPT
Oct 17, 2024 Resolved
Consumer Confidence Rule
OTHER
Jan 13, 2020 Resolved
Consumer Confidence Rule
OTHER
Nov 6, 2018 Resolved

Full record since 1988

EPA's records for Cadiz Village PWS go back to 1988. Before October 19, 2016 they list 42 health-based violations (42 resolved) and 23 monitoring or reporting violations.

Violations that began in Health-based Monitoring and reporting
1980s 0 6
1990s 33 16
2000s 1 0
2010 to October 18, 2016 8 1
October 19, 2016 to 2019 1 1
2020s 6 3

Most recent health-based violation before October 19, 2016: Long Term 2 Enhanced Surface Water Treatment Rule, began July 2013, Resolved.

Show all 42 health-based violations before October 19, 2016
Contaminant Start date Status
Long Term 2 Enhanced Surface Water Treatment Rule
Treatment technique failure
Jul 1, 2013 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.083 mg/L, federal limit 0.08 mg/L (at or just above the limit)
Apr 1, 2011 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
Jan 1, 2011 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jan 1, 2011 Resolved
Surface Water Treatment Rule
Treatment technique failure
Dec 1, 2010 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.089 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
Oct 1, 2010 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.085 mg/L, federal limit 0.08 mg/L (1.1 times the limit)
Jul 1, 2010 Resolved
Total Coliform
Contaminant limit exceeded
Jul 1, 2010 Resolved
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.082 mg/L, federal limit 0.08 mg/L (at or just above the limit)
Apr 1, 2005 Resolved
Surface Water Treatment Rule
Treatment technique failure
Dec 1, 1998 Resolved
Surface Water Treatment Rule
Treatment technique failure
Feb 1, 1998 Resolved
Surface Water Treatment Rule
Treatment technique failure
Dec 1, 1996 Resolved
Surface Water Treatment Rule
Treatment technique failure
Nov 1, 1996 Resolved
Surface Water Treatment Rule
Treatment technique failure
Oct 1, 1996 Resolved
Surface Water Treatment Rule
Treatment technique failure
Sep 1, 1996 Resolved
Surface Water Treatment Rule
Treatment technique failure
Aug 1, 1996 Resolved
Surface Water Treatment Rule
Treatment technique failure
Dec 1, 1995 Resolved
Total Coliform
Contaminant limit exceeded
Dec 1, 1995 Resolved
Surface Water Treatment Rule
Treatment technique failure
Sep 1, 1995 Resolved
Surface Water Treatment Rule
Treatment technique failure
Aug 1, 1995 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jul 1, 1995 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jun 1, 1995 Resolved
Surface Water Treatment Rule
Treatment technique failure
Apr 1, 1995 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jan 1, 1995 Resolved
Surface Water Treatment Rule
Treatment technique failure
Dec 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Nov 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Oct 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Sep 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Aug 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jul 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jun 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
May 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Apr 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Mar 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Feb 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jan 1, 1994 Resolved
Surface Water Treatment Rule
Treatment technique failure
Dec 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Nov 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Oct 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Sep 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Aug 1, 1993 Resolved
Surface Water Treatment Rule
Treatment technique failure
Jul 1, 1993 Resolved

Enforcement actions

Ohio regulators took 1 formal enforcement action against Cadiz Village PWS and issued 1 boil water order between 1994 and 2025. The most recent was a boil water order in June 2025.

Date By Action Violations covered
Jun 27, 2025 Ohio Boil water order 1 violation (1 health-based): Interim Enhanced Surface Water Treatment Rule
Apr 29, 1994 Ohio Compliance order (no penalty) 17 violations (10 health-based): Surface Water Treatment Rule

What the violations mean

Interim Enhanced Surface Water Treatment Rule

5 incidents

The system did not meet a filtration or treatment requirement for surface water

Inadequate treatment of surface water can let pathogens such as Cryptosporidium and Giardia through

LEAD AND COPPER RULE REVISIONS

1 incident

The system did not complete a treatment step or action that the LEAD AND COPPER RULE REVISIONS requires (a treatment technique violation).

The utility had to notify customers about this violation.

Stage 1 Disinfection Byproducts Rule

1 incident

The system did not meet a treatment requirement of the Stage 1 Disinfectants and Disinfection Byproducts Rule

Byproducts form when disinfectants react with natural material in water. Long-term exposure above federal limits may increase cancer risk

Where the water comes from

Cadiz Village PWS draws water from 1 surface water intake. 2 other community water systems buy water from Cadiz Village PWS.

Community systems that buy water from it

Annual water quality report

Cadiz Village PWS must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.

Where the state allows it, systems serving fewer than 10,000 people may publish the report in a local newspaper or news site instead of mailing it, and must provide a copy on request.

Find a posted report with EPA's Consumer Confidence Report search

Testing your own water

To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by Ohio.