Public water system record

Trampas MDWCA

Serves an area of Taos County, NM · 132 people served

Federal records show 25 health-based violations and 17 monitoring/reporting issues for Trampas MDWCA in the last ten years. The most serious issue in this window was a resolved LEAD AND COPPER RULE REVISIONS violation.

  • NM3507629
  • TRAMPAS
  • NM
  • 132 served

System profile

Source water Groundwater
ZIP 87576
EPA system ID NM3507629

Verify this system on EPA ECHO →

Health-based violations, last 10 years
25
Resolved
25
Unresolved
0
Any acute record
No
Monitoring issues, last 10 years
17

Key facts

  • Trampas MDWCA draws water from 2 wells.
  • Highest measured level in the last 10 years: Combined Uranium, 42 µg/L, federal limit 30 µg/L (1.4 times the limit), 2017.
  • Most recent formal enforcement: compliance order (no penalty) by New Mexico, October 2016.
  • Record on file since 1984, with 31 health-based violations before October 19, 2016.
  • Lead pipe inventory: 0 lead and 0 unknown out of 51 service lines.

Check whether Trampas MDWCA serves your address

Address suggestions by Mapbox

Health-based violations

Since October 2016

Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.

Contaminant Rule family Start date Status Acute
LEAD AND COPPER RULE REVISIONS
Treatment technique failure
350 Oct 17, 2024 Resolved No
Groundwater Rule
Treatment technique failure
140 Oct 2, 2024 Resolved No
Groundwater Rule
Treatment technique failure
140 Oct 2, 2024 Resolved No
Groundwater Rule
Treatment technique failure
140 Oct 2, 2024 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 40 µg/L, federal limit 30 µg/L (1.3 times the limit)
340 Jan 1, 2020 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 40 µg/L, federal limit 30 µg/L (1.3 times the limit)
340 Oct 1, 2019 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 40 µg/L, federal limit 30 µg/L (1.3 times the limit)
340 Jul 1, 2019 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 41 µg/L, federal limit 30 µg/L (1.4 times the limit)
340 Apr 1, 2019 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 41 µg/L, federal limit 30 µg/L (1.4 times the limit)
340 Jan 1, 2019 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 41 µg/L, federal limit 30 µg/L (1.4 times the limit)
340 Oct 1, 2018 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 41 µg/L, federal limit 30 µg/L (1.4 times the limit)
340 Jul 1, 2018 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 41 µg/L, federal limit 30 µg/L (1.4 times the limit)
340 Apr 1, 2018 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 41 µg/L, federal limit 30 µg/L (1.4 times the limit)
340 Jan 1, 2018 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 42 µg/L, federal limit 30 µg/L (1.4 times the limit)
340 Oct 1, 2017 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 39 µg/L, federal limit 30 µg/L (1.3 times the limit)
340 Jul 1, 2017 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 39 µg/L, federal limit 30 µg/L (1.3 times the limit)
340 Apr 1, 2017 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 38 µg/L, federal limit 30 µg/L (1.3 times the limit)
340 Jan 1, 2017 Resolved No
Combined Uranium
Contaminant limit exceeded
Measured 37 µg/L, federal limit 30 µg/L (1.2 times the limit)
340 Oct 1, 2016 Resolved No
Groundwater Rule
Treatment technique failure
140 Jan 16, 2015 Resolved No
Groundwater Rule
Treatment technique failure
140 Jan 16, 2015 Resolved No
Groundwater Rule
Treatment technique failure
140 Jan 16, 2015 Resolved No
Groundwater Rule
Treatment technique failure
140 Oct 21, 2014 Resolved No
Groundwater Rule
Treatment technique failure
140 Oct 21, 2014 Resolved No
Groundwater Rule
Treatment technique failure
140 Oct 21, 2014 Resolved No
Groundwater Rule
Treatment technique failure
140 Oct 21, 2014 Resolved No

Monitoring and reporting issues

Since October 2016

Missed tests or reports, not contaminants found above a limit.

Issue Start date Status
Consumer Confidence Rule
OTHER
Jul 1, 2025 Resolved
LEAD AND COPPER RULE REVISIONS
RPT
Oct 17, 2024 Resolved
Consumer Confidence Rule
OTHER
Jul 1, 2021 Resolved
Consumer Confidence Rule
OTHER
Jul 1, 2020 Resolved
Public Notice
OTHER
Apr 28, 2019 Resolved
Public Notice
OTHER
Dec 30, 2018 Resolved
Public Notice
OTHER
Jun 23, 2018 Resolved
Public Notice
OTHER
Apr 13, 2018 Resolved
Public Notice
OTHER
Apr 13, 2018 Resolved
Public Notice
OTHER
Apr 13, 2018 Resolved
Public Notice
OTHER
Sep 7, 2017 Resolved
Public Notice
OTHER
Aug 10, 2017 Resolved
Public Notice
OTHER
Aug 10, 2017 Resolved
Public Notice
OTHER
Apr 20, 2017 Resolved
Public Notice
OTHER
Mar 24, 2017 Resolved
Public Notice
OTHER
Jan 31, 2014 Resolved
Lead and Copper Rule
Monitoring and reporting
Oct 1, 2013 Resolved

Full record since 1984

EPA's records for Trampas MDWCA go back to 1984. Before October 19, 2016 they list 31 health-based violations (31 resolved) and 29 monitoring or reporting violations.

Violations that began in Health-based Monitoring and reporting
1980s 0 6
1990s 0 5
2000s 0 5
2010 to October 18, 2016 31 13
October 19, 2016 to 2019 12 11
2020s 5 4

Most recent health-based violation before October 19, 2016: Combined Uranium, began October 2016, Resolved.

Show all 31 health-based violations before October 19, 2016
Contaminant Start date Status
Combined Uranium
Contaminant limit exceeded
Measured 37 µg/L, federal limit 30 µg/L (1.2 times the limit)
Oct 1, 2016 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 40 µg/L, federal limit 30 µg/L (1.3 times the limit)
Jul 1, 2016 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 40 µg/L, federal limit 30 µg/L (1.3 times the limit)
Apr 1, 2016 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 40 µg/L, federal limit 30 µg/L (1.3 times the limit)
Jan 1, 2016 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 52 pCi/L, federal limit 15 pCi/L (3.5 times the limit)
Oct 1, 2015 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 38 µg/L, federal limit 30 µg/L (1.3 times the limit)
Oct 1, 2015 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 56 pCi/L, federal limit 15 pCi/L (3.7 times the limit)
Jul 1, 2015 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 37 µg/L, federal limit 30 µg/L (1.2 times the limit)
Jul 1, 2015 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 58 pCi/L, federal limit 15 pCi/L (3.9 times the limit)
Apr 1, 2015 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 37 µg/L, federal limit 30 µg/L (1.2 times the limit)
Apr 1, 2015 Resolved
Groundwater Rule
Treatment technique failure
Jan 16, 2015 Resolved
Groundwater Rule
Treatment technique failure
Jan 16, 2015 Resolved
Groundwater Rule
Treatment technique failure
Jan 16, 2015 Resolved
Groundwater Rule
Treatment technique failure
Jan 16, 2015 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 56 pCi/L, federal limit 15 pCi/L (3.7 times the limit)
Jan 1, 2015 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 38 µg/L, federal limit 30 µg/L (1.3 times the limit)
Jan 1, 2015 Resolved
Groundwater Rule
Treatment technique failure
Oct 21, 2014 Resolved
Groundwater Rule
Treatment technique failure
Oct 21, 2014 Resolved
Groundwater Rule
Treatment technique failure
Oct 21, 2014 Resolved
Groundwater Rule
Treatment technique failure
Oct 21, 2014 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 40 µg/L, federal limit 30 µg/L (1.3 times the limit)
Oct 1, 2014 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 16 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
Jul 1, 2014 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 38 µg/L, federal limit 30 µg/L (1.3 times the limit)
Jul 1, 2014 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 18 pCi/L, federal limit 15 pCi/L (1.2 times the limit)
Apr 1, 2014 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 34 µg/L, federal limit 30 µg/L (1.1 times the limit)
Apr 1, 2014 Resolved
Gross Alpha, Excl. Radon and U
Contaminant limit exceeded
Measured 17 pCi/L, federal limit 15 pCi/L (1.1 times the limit)
Jan 1, 2014 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 31 µg/L, federal limit 30 µg/L (at or just above the limit)
Oct 1, 2012 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 35 µg/L, federal limit 30 µg/L (1.2 times the limit)
Jul 1, 2012 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 35 µg/L, federal limit 30 µg/L (1.2 times the limit)
Apr 1, 2012 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 35 µg/L, federal limit 30 µg/L (1.2 times the limit)
Jan 1, 2012 Resolved
Combined Uranium
Contaminant limit exceeded
Measured 35 µg/L, federal limit 30 µg/L (1.2 times the limit)
Oct 1, 2011 Resolved

Enforcement actions

New Mexico regulators took 1 formal enforcement action against Trampas MDWCA in 2016. The most recent was a compliance order (no penalty) in October 2016.

Date By Action Violations covered
Oct 20, 2016 New Mexico Compliance order (no penalty) 29 violations (28 health-based): Combined Uranium, Gross Alpha, Excl. Radon and U, Lead and Copper Rule

What the violations mean

Combined Uranium

14 incidents

Test results for Combined Uranium were above the federal limit (a maximum contaminant level violation).

The utility had to notify customers about each of these violations.

Groundwater Rule

10 incidents

The system did not complete a treatment step or action that the Groundwater Rule requires (a treatment technique violation).

The utility had to notify customers about each of these violations.

LEAD AND COPPER RULE REVISIONS

1 incident

The system did not complete a treatment step or action that the LEAD AND COPPER RULE REVISIONS requires (a treatment technique violation).

The utility had to notify customers about this violation.

Where the water comes from

Trampas MDWCA draws water from 2 wells.

Annual water quality report

Trampas MDWCA must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.

Systems serving 500 or fewer people may meet the rule by telling customers the report is available on request, so you may need to ask Trampas MDWCA for a copy.

Find a posted report with EPA's Consumer Confidence Report search

Testing your own water

To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by New Mexico.