Public water system record
Pine Grove Comm Serv Dist
Serves Pine Grove, Amador County, CA · 1,141 people served
Federal records show 1 health-based violation and 1 monitoring/reporting issue for Pine Grove Comm Serv Dist in the last ten years. The most serious issue in this window was a resolved Lead and Copper Rule violation.
System profile
- Health-based violations, last 10 years
- 1
- Resolved
- 1
- Unresolved
- 0
- Any acute record
- No
- Monitoring issues, last 10 years
- 1
Key facts
- Pine Grove Comm Serv Dist buys its water from Awa Buckhorn Plant.
- Most recent formal enforcement: compliance order (no penalty) by California, October 2014.
- Record on file since 1993, with 7 health-based violations before October 19, 2016.
- Lead pipe inventory: 0 lead and 0 unknown out of 401 service lines.
Check whether Pine Grove Comm Serv Dist serves your address
Health-based violations
Since October 2016Violation data reflects EPA records through March 2026. For the most current status, visit the EPA ECHO database.
| Contaminant | Rule family | Start date | Status | Acute |
|---|---|---|---|---|
|
Lead and Copper Rule
Treatment technique failure
|
350 | Sep 7, 2006 | Resolved | No |
Monitoring and reporting issues
Since October 2016Missed tests or reports, not contaminants found above a limit.
| Issue | Start date | Status |
|---|---|---|
|
Lead and Copper Rule
Monitoring and reporting
|
Jul 1, 2025 | Active |
Full record since 1993
EPA's records for Pine Grove Comm Serv Dist go back to 1993. Before October 19, 2016 they list 7 health-based violations (7 resolved) and 4 monitoring or reporting violations.
| Violations that began in | Health-based | Monitoring and reporting |
|---|---|---|
| 1990s | 1 | 1 |
| 2000s | 4 | 2 |
| 2010 to October 18, 2016 | 2 | 1 |
| 2020s | 0 | 1 |
Most recent health-based violation before October 19, 2016: Total Trihalomethanes (TTHMs), began July 2014, Resolved.
Show all 7 health-based violations before October 19, 2016
| Contaminant | Start date | Status |
|---|---|---|
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.0815 mg/L, federal limit 0.08 mg/L (at or just above the limit)
|
Jul 1, 2014 | Resolved |
|
Total Trihalomethanes (TTHMs)
Contaminant limit exceeded
Measured 0.081 mg/L, federal limit 0.08 mg/L (at or just above the limit)
|
Jul 1, 2011 | Resolved |
|
Lead and Copper Rule
Treatment technique failure
|
Sep 7, 2006 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.082 mg/L, federal limit 0.06 mg/L (1.4 times the limit)
|
Apr 1, 2006 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.0766 mg/L, federal limit 0.06 mg/L (1.3 times the limit)
|
Jan 1, 2006 | Resolved |
|
Haloacetic Acids (HAA5)
Contaminant limit exceeded
Measured 0.063 mg/L, federal limit 0.06 mg/L (1.1 times the limit)
|
Oct 1, 2005 | Resolved |
|
Total Coliform
Contaminant limit exceeded
|
Nov 1, 1993 | Resolved |
Enforcement actions
California regulators took 5 formal enforcement actions against Pine Grove Comm Serv Dist between 2004 and 2014, filed as 6 records in EPA's data. The most recent was a compliance order (no penalty) in October 2014.
| Date | By | Action | Violations covered |
|---|---|---|---|
| Oct 23, 2014 | California | Compliance order (no penalty) | 1 violation (1 health-based): Total Trihalomethanes (TTHMs) |
| Oct 24, 2011 | California | Compliance order (no penalty) | 1 violation (1 health-based): Total Trihalomethanes (TTHMs) |
| Mar 18, 2010 | California | Compliance order (no penalty) | 1 violation: Total Coliform |
| Oct 23, 2006 | California | Compliance order (no penalty) | 1 violation (1 health-based): Lead and Copper Rule |
| Oct 29, 2004 | California | Compliance order (no penalty) | 2 violations: Total Trihalomethanes (TTHMs), Haloacetic Acids (HAA5) |
What the violations mean
Lead and Copper Rule
1 incidentThe system did not complete a treatment step or action that the Lead and Copper Rule requires (a treatment technique violation).
The utility had to notify customers about this violation.
Where the water comes from
Pine Grove Comm Serv Dist buys its water from Awa Buckhorn Plant. It lists no wells or intakes of its own.
Buys water from
- Awa Buckhorn Plant Sutter Creek, CA
Annual water quality report
Pine Grove Comm Serv Dist must give its customers an annual water quality report (Consumer Confidence Report) by July 1, with the levels its tests found in the previous year.
Where the state allows it, systems serving fewer than 10,000 people may publish the report in a local newspaper or news site instead of mailing it, and must provide a copy on request.
Find a posted report with EPA's Consumer Confidence Report search
Testing your own water
To test the water at your tap, or a private well this record does not cover, use a laboratory certified for drinking water by California.
Certified drinking water labs by state EPA guidance for private wells